Benchtop Multi-parameter Water Quality Meter Conductivity IP54 Protection

This desktop tester has four models (PC100/PD100/CD100/PCD100) to test pH, ORP, conductivity and DO with ATC. It has a high-res white backlit screen, auto-calibration and status indicators, storing 450 data sets exportable via flash drive or optional wireless printer. Rated IP54, it comes with a flexible probe holder and matched calibration solutions for stable, accurate water quality measurement.

    SKU: BENCHTOP-Classical series (Multi parameter) Categories: , Tag:

    Features

    💎 High-res display screen with white backlight, easy to read

    💎 Automatic calibration, ATC measurement, parameter setup

    💎 Automatic reading stable indication, calibration indication

    💎 Data storage: 450 readings

    💎 Data export: Flash disk/ Wireless printer (the printer is optional)

    💎 Equipped with a flexible probe holder and pH buffer solutions for convenient use

    💎 Protection class: IP54

    💎 Equipped with various electrode holders and standard solutions, suitable for measuring different parameters.

     

    Technical Parameter:

    Model PC100 PD100 CD100 PCD100
    Parameter pH/mV.°C
    mV(ORP).°C
    Cond/TDS/Sal./Res.°C
    DO.°C
    pH Measurement range (-2.00–20.00)pH
    Resolution 0.1/0.01
    Accuracy ±0.01pH ±one digit
    Calibration points 1, 2, 3pts automatic
    ATC range (-9.9–130.0)°C/(14.18–266.0)°F
    ORP Measurement range (-1999.9–+1999.9)mV
    Resolution 1
    Accuracy ±0.1%F.S ±one digit
    Conductivity Measurement range 0–200.0mS/cm, Auto-ranging:0–19.99μS/cm; 20.0–199.9μS/cm; 200–1999μS/cm;2.00–19.99mS/cm; 20.00–199.9mS/cm;TDS: 0–100.0g/LResistivity:5.00Ω·cm–100.0MΩ·cmSalinity:0–100ppt
    Calibration points one point
    Resolution 0.001
    ATC range (0.0–50.0)°C/(32.0–122.0)°F
    Accuracy ±1.0%F.S ±one digit
    DO Measurement range (0.00–20.00)mg/L
    Accuracy ±0.30 mg/L
    DO saturation (0.0–200.0)%
    Automatic barometric pressure compensation (0–200.0)kPa
    Automatic temperature compensation (0.0–50.0)°C/(32.0–122.0)°F
    Manual salinity compensation 0–45ppt
    Temperature Measurement range (-9.9–130.0)°C/(14.18–266.0)°F
    Accuracy ±0.2°C
    Others Data export Flash disk/Printer
    Power supply DC12V
    Test kit Meter
    Plastic ATC pH probe 201T
    Glass ATC conductivity probe CON201TG,K=1.0
    Polarographic DO probe DO01-2M,cable length:2m
    pH buffer solution:pH4.00/7.00/10.01,50mL,one for each
    Standard Cond solution:84μS/1413μS/12.88mS/cm, 50mL,one for each
    Membrane refill solution:DOS-01,30mL,1btl
    Membrane sensor caps DOSC:3pcs/group,1pkg
    Power adaptor:1pc
    Flexible probe holder DF01:1pc