Ophthalmology Cassette Sterilizer Laboratory Autoclave Sterilizing Dental Cassette Sterilizer 6L Dentistry Steam Sterilizer Wholesale

Machine dimensions
580*460*190mm
YJ-5000/YJ-6000cassette size (external)
480*196*80mm/570*210*80mm
YJ-5000/YJ-6000 cassette size (internal)
380*180*78mm/480*180*78mm
SK-5000/SK-6000chamber volume
5.2L/6.0L
Reservoir volume
3.4L
Electrical rating
AC220V±10%                     50Hz±1Hz 6 A Max 1.3kVA
Steam temperature
110-135℃ (Selectable)

    Description

    1. The sterilization effect is reliable and rapid. The whole process ofnon-wrapped sterilization takes 9 minutes, which is suitable formulti-department equipment operation and emergency.
    2. It is easy to operate, the system operation is displayed on the screen; Sterilization procedures can be safely interrupted at any time.
    3. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
    4. It is suitable for sterilization of instruments containing cavity andsolid instruments, and it can be non-wrapped sterilization
    3. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
    4. It is suitable for sterilization of instruments containing cavity andsolid instruments, and it can be non-wrapped sterilization

    Press button
    Sterilization temperature
    Sterilization time(min)
    Dryness time(min)
    Appliance
    110-135°c
    4-99
    0-99
    Package appliance
    110-135°c
    4-99
    0-99
    Nonmatal appliance
    110-135°c
    4-99
    0-99

     

    1. The shortest sterilization cycle only needs 6-7 minutes.
    2. Compared with the autoclave with a longer sterilization cycle, this quicker autoclave prolongs the lifetime of the medical appliances relatively, because the cycle time of the sterilized appliances exposed to the high temperature is less.
    3. Three press buttons for different sterilization programs, the time and temperature of sterilization can be set freely according to the user’s needs.
    4. Under the circumstances of unqualified water and water shortage in the tank, it gives an alarm signal and flashes on the display. for the low temperature and the low pressure during the sterilization process, it will stop the sterilization cycle automatically, the error information is displayed and printed at the same time.
    5. Small dimension, light weight, wide ambient working condition, easy to operate. the cassette is also a good medical appliance container for temporary deposit and carry.
    After sterilization program selected and start key pressed, the steam generator heats to an optimum temperature, then certain volume of distilled wateris pumped into the generator and immediately converted into steam, a wall of steam is injected into the steam courses through the cassette, the unclean and cold air stored in the cassette at the first beginning is wholly removed.
    1. Operates easily
    2. english language operation
    3. the signal matches the printer, but real-line record antiseptic process
    4. the card box’s be ultra-thin wall design ,causes the warning and the radiation is quicker
    5. 0.22micron living thing filter