Machine dimensions
|
580*460*190mm
|
|
YJ-5000/YJ-6000cassette size (external)
|
480*196*80mm/570*210*80mm
|
|
YJ-5000/YJ-6000 cassette size (internal)
|
380*180*78mm/480*180*78mm
|
|
SK-5000/SK-6000chamber volume
|
5.2L/6.0L
|
|
Reservoir volume
|
3.4L
|
|
Electrical rating
|
AC220V±10% 50Hz±1Hz 6 A Max 1.3kVA
|
|
Steam temperature
|
110-135℃ (Selectable)
|
Description
1. The sterilization effect is reliable and rapid. The whole process ofnon-wrapped sterilization takes 9 minutes, which is suitable formulti-department equipment operation and emergency.
2. It is easy to operate, the system operation is displayed on the screen; Sterilization procedures can be safely interrupted at any time.
3. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
4. It is suitable for sterilization of instruments containing cavity andsolid instruments, and it can be non-wrapped sterilization
3. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
4. It is suitable for sterilization of instruments containing cavity andsolid instruments, and it can be non-wrapped sterilization
|
Press button
|
Sterilization temperature
|
Sterilization time(min)
|
Dryness time(min)
|
|
Appliance
|
110-135°c
|
4-99
|
0-99
|
|
Package appliance
|
110-135°c
|
4-99
|
0-99
|
|
Nonmatal appliance
|
110-135°c
|
4-99
|
0-99
|
2. Compared with the autoclave with a longer sterilization cycle, this quicker autoclave prolongs the lifetime of the medical appliances relatively, because the cycle time of the sterilized appliances exposed to the high temperature is less.
3. Three press buttons for different sterilization programs, the time and temperature of sterilization can be set freely according to the user’s needs.
4. Under the circumstances of unqualified water and water shortage in the tank, it gives an alarm signal and flashes on the display. for the low temperature and the low pressure during the sterilization process, it will stop the sterilization cycle automatically, the error information is displayed and printed at the same time.
1. Operates easily
2. english language operation
3. the signal matches the printer, but real-line record antiseptic process
4. the card box’s be ultra-thin wall design ,causes the warning and the radiation is quicker
5. 0.22micron living thing filter